Clinical Microbiology Laboratories: Pre‑treatment of urine, sputum, stool, wound swabs, and positive blood culture bottles; automated dilution, homogenization, and inoculation for bacterial and fungal culture and antimicrobial susceptibility testing (AST).
Food Safety & Quality Control: Homogenization and serial dilution of food samples (meat, dairy, produce, etc.) for analysis of coliforms, Salmonella, Listeria, and Total Viable Counts (TVC) in compliance with ISO, AOAC, and GB standards.
Pharmaceutical Microbiology QC: Sample preparation for sterility testing, Microbial Limit Tests (MLT), and processing of environmental monitoring samples within GMP‑compliant facilities.
Environmental & Public Health Testing: Processing of water, air filters, and surface swab samples for pathogen detection and hygiene surveillance.
Research & Academic Institutions: Standardized sample lysis (bead‑beating), dilution, and plating for metagenomics, isolate screening, and Antimicrobial Resistance (AMR) studies.
Clinical Microbiology Laboratories / Infection Control Departments
Food & Drug Control Institutes / Third‑party Testing Laboratories
Pharmaceutical QA/QC Microbiology Labs
Centers for Disease Control and Prevention (CDC) / Public Health Laboratories
University & Research Institute Microbiology Labs
Core Advantages
Featuring fully or semi‑automated enclosed processing, the system significantly reduces cross‑contamination risks and operator exposure to hazardous pathogens. It delivers exceptional dilution accuracy, uniform lysis/homogenization, and programmable protocols. Compared to manual methods, it dramatically increases throughput and ensures superior inter‑operator reproducibility.
Key Technical Parameters (Typical)
ParameterSpecification (Example)Compatible Sample TypesLiquids (urine, broth), semi‑solids (stool, sputum), swabs, solid food homogenatesProcessing ModesAutomated serial dilution (1:10, 1:100...), vortex/homogenization, bead‑beating lysis, spiral/streak plating (model dependent)Dilution Accuracy≤ ±1% (dependent on pipetting system)Homogenization Speed / TimeAdjustable; e.g., 3,000–10,000 rpm; programmable from 10–300 sBead‑Beating ChamberCompatible with disposable sterile tubes; optional cooling module available to prevent thermal degradationThroughput20–60 samples/hour (protocol dependent)Consumables CompatibilityStandard Ø90 mm Petri dishes, deep‑well plates; customizable inoculation patternsBiosafety DesignEnclosed processing chamber with HEPA filtration, UV sterilization, and independent fluidic pathways to prevent cross‑contaminationProtocol Storage≥50 user‑definable programs